SHAFTWALL / AREA SEPARATION WALL product catalog …
Cavity shaftwalls are constructed utilizing one of two methods: masonry/CMU or light-gauge steel and gypsum. Gypsum drywall shaftwall construction has become the …

Cavity shaftwalls are constructed utilizing one of two methods: masonry/CMU or light-gauge steel and gypsum. Gypsum drywall shaftwall construction has become the …
USG Cavity Shaft Wall System is the only wall for which a UL smoke and fire damper test is ... Metal studs. 4. Metal shaftwall systems. 5. Gypsum board finishing. 6.Trim and accessories. 2. RELATED WORK SPECIFIED ELSEWHERE 1. See Section 09900 PAINTING AND FINISHING for gypsum board prime and finish coats. 3. SUBMITTALS
For a 3/4" product that also provides mold and moisture resistance use Gold Bond® XP ® Ultra-Shield FS® Gypsum Board. Check the Fire and Safety Information for a more complete explanation of how fire …
National Gypsum Company Cavity Shaftwall Systems may be constructed with C-T, C-H or I-Stud shaftwall framing. Features/Benefits m Manufactured to meet ASTM C 1396 and ASTM C 1658. m Cavity Shaftwall Systems are very lightweight compared to conventional shaftwalls, weighing approximately 10 lbs. per sq. ft. of wall when finished with a
The Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, …
National Gypsum Company 2001 Rexford Road Charlotte, NC 28211 (704) 365-7300 Technical Information: 1-800-NATIONAL ... Internet Home Page: 09260/NGC Buyline: 1100 º. DESCRIPTION Cavity Shaftwall systems are a nonload-bearing drywall parti-tion made up of two basic components: gypsum board and metal …
What is the biggest challenge to creating fire-rated wood-frame assemblies? Maintaining the fire rating where the assemblies intersect. In this article, we take a closer look at fire-rated assemblies for shaft enclosure and area separation firewalls to show how The Wood Book™ from National Gypsum Company provides fire-rating continuity solutions. ...
application details for National Gypsum Cavity Shaftwall Systems or Area Separation Fire Wall Systems in NGC Construction Guïde, or with other fire-resistance-rated designs. Install fire-rated assemblies in accordance with the details found in the UL Fire Resistance Directory or Gypsum Association, GA-600, Fire Resistance Design Manual.
What is a Cavity Shaftwall System? A cavity shaftwall is a non-load-bearing, 1- through 4-hour, fire-rated partition constructed from one side and used to enclose elevator shafts, stairs and mechanical …
3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FRAMING DETAILS J-Track with ends slotted DETAIL A I-Stud
National Gypsum's comprehensive Design & Resource Center provides access to a digital library of tools, educational resources and answers to some of your toughest building questions. Your Guides for Building a Better Future - Technical resources to help you select and specify the right products.
The gypsum board cavity shaftwall system turned 50 in 2023, having been developed for use in the World Trade Center that opened in 1973. The buildings' designers tasked gypsum board …
National Gypsum Company is the exclusive service provider for products manufactured by Gold Bond Building Products, LLC, PermaBASE Building Products, LLC and ProForm Finishing Products, LLC. ...
NGC Testing Services | ASTM E119 Fire Test. For over 50 years, NGC Testing Services has provided the most efficient and cost-effective solution for full-scale fire, acoustical, structural/building envelope, and analytical …
Gypframe 146 TI 90 Tabbed 'I' Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Two layers of Gyproc FireLine 12.5mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4200mm.
Georgia-Paciic Gypsum; National Gypsum; PABCO Gypsum; and United States Gypsum. Check the speciic ire or sound assembly to be constructed for the details required to achieve the desired rating. C-T SHAFTWALL/STAIRWELL STUD Engineered to maintain shaftwall integrity, ClarkDietrich C-T cavity shaftwall studs are punched with
CertainTeed Gypsum 750 E Swedesford Road Decatur, GA 30035 Georgia-Pacific Gypsum, LLC 2861 Miller Road National Gypsum 2001 Rexford Road Charlotte, NC 28211 12950 Worldgate Drive, Suite 700 Herndon, VA 20170 Operating Company, LLC Continental Building Products Section 1207 (2015 IBC) Section 2203.1 Section 1023 …
of the system have enabled the USG Cavity Shaft Wall System to dominate the high−rise shaft−enclosure market in most geographic areas. Because it is a drywall system, it offers the low cost of drywall, and its easy installation features make it economical to install. The basic 2−hr. fire−rated system weighs just 9 lb/sq. ft. and
* The Cavity Shaftwall system was developed to enclose elevator shafts, stairwells and other vertical chases in buildings where it is advantageous to erect these walls from one side only and where fire resistance and resistance to air pressures are required. ... For information on system requirements contact National Gypsum's Technical Service ...
For a 3/4" product that also provides mold and moisture resistance use Gold Bond® XP ® Ultra-Shield FS® Gypsum Board. Check the Fire and Safety Information for a more complete explanation of how fire resistance ratings work. APPLICATIONS: For single-layer - steel stud and cavity shaftwall systems. The greater thickness provides increased ...
The British Gypsum Gypframe Metal I Stud 92I90 is a robust component used in British Gypsum ShaftWall, GypLyner iwl, and select GypWall systems. It offers maximum impact resistance, improved load-carrying capacity, and enhanced screw retention, ensuring durability and compliance with EN 14195.
The system is finished with fire rated gypsum board to complete and achieve the designated fire rating. C-T Studs are available in 22mils (25ga), 33mils (20ga) and 43mils (18ga). ... Two-Hour Cavity Shaftwall (Non …
Type C gypsum board will maintain its material integrity in a fire condition better than Type X gypsum board. The assembly must be constructed with the components listed in the UL design. If the design was tested with Type C gypsum board in the ceiling location, then Type C gypsum board must be installed.
Gypframe 60 I 70 'I' Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Two layers of Gyproc FireLine 12.5mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4200mm.
CGC Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are ... other multilayer gypsum panel systems because it is installed from one side, leaving the shaft free of scaffolding. The assemblies are constructed of ...
Gypframe 60 I 70 'I' Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc FireLine 12.5mm with an outer layer of Gyproc Habito 12.5mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 3000mm.
National Gypsum Company Cavity Shaftwall Systems may be constructed with C-T, C-H or I-Stud shaftwall framing. Lightweight. Cavity Shaftwall Systems are very lightweight compared to conventional shaftwalls, weighing approximately 10 lbs. per sq. ft. of wall when finished with two layers of 1/2" Fire-Shield C Gypsum Board. Economical. Shafts can be
4 USG Shaft Wall Systems Overview USG shaft wall systems are non-loadbearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components
Gypframe 60 I 70 'I' Studs at 600mm centres with Gyproc CoreBoard 19mm between studs, secured by Gypframe G102 Retaining Channel. Inner layer of Gyproc Habito 12.5mm with an outer layer of Gyproc FireLine 12.5mm to non-shaft side and 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity. For heights up to 4200mm.
The system includes gypsum liner panels, gypsum panels and cement board, interior finishing products and framing components. The Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other vertical shafts. ...